Insulation Thickness Chart: R-38 to R-60 by Material

By Marko VisicBSc Physics, University of Ljubljana

Codes and ENERGY STAR give R-values; your attic has a ruler. This chart turns one into the other for batts, blown-in fiberglass, cellulose and spray foam.

R-38 insulation is 12½ inches thick as an Owens Corning PINK Next Gen batt. Blown in, it takes 13½ inches of AttiCat fiberglass, or 11.2 inches of Greenfiber cellulose that settles to 10.4. Spray foam gets there thinner: about 10.3 inches of open-cell or 5.1 inches of closed-cell foam at Huntsman’s ratings.

R-38 as a fiberglass batt

12½ inbattfiberglass13½ inblownfiberglass10.4 incellulosesettled10.3 inopen-cellfoam5.1 inclosed-cellfoam
Five insulations at R-38, drawn to one scale; the dashed line is where cellulose is blown to before it settles.

Insulation thickness chart

Thickness depends on the material as much as the R-value. The batts are Owens Corning’s PINK Next Gen, the blown fiberglass its AttiCat, the cellulose Greenfiber’s SANCTUARY with the depth to blow it in and the depth it settles to, and the spray foams Huntsman’s at the R per inch it rates them.

Inches of insulation for each R-value. Foam depths divide the R-value by Huntsman's ratings per inch.
R-valueBattBlown fiberglassCellulose, blown / settledOpen-cell foamClosed-cell foam
R-133½ in5 in3.9 / 3.6 in3.5 in1.8 in
R-196½ in7 in5.7 / 5.3 in5.1 in2.6 in
R-226¾ in8 in6.6 / 6.1 in5.9 in3 in
R-3010 in10¾ in8.9 / 8.3 in8.1 in4.1 in
R-3812½ in13½ in11.2 / 10.4 in10.3 in5.1 in
R-4914 in17 in14.3 / 13.3 in13.2 in6.6 in
R-60no batt20½ in17.3 / 16.1 in16.2 in8.1 in

R-38 insulation thickness

An R-38 PINK Next Gen batt is 12½ inches thick. Its R-38C batt is 10¼ inches: Owens Corning made it for cathedral ceilings, where a standard R-38 batt squeezed into the cavity with a vent baffle gave only about R-35, by its 2012 data sheet. Blown in, R-38 takes 13½ inches of AttiCat fiberglass, about 19 bags for every thousand square feet, or 11.2 inches of Greenfiber cellulose that settles to 10.4.

Spray foam reaches R-38 with less depth: 5.1 inches of closed-cell foam at R-7.4 per inch, or 10.3 inches of open-cell at R-3.7.

Attic insulation depth by climate zone

ENERGY STAR’s retrofit table, based on the 2021 IECC, gives an R-value for an attic with no insulation and one for an attic that already has three to four inches. The table below puts the first in inches of blown fiberglass and settled cellulose.

ENERGY STAR's recommended levels for existing wood-framed homes, with the depth of an uninsulated attic's level.
ZoneUninsulated atticBlown fiberglassCellulose, settledAdd to existingFloor
1R-3010¾ in8.3 inR-25R-13
2R-4917 in13.3 inR-38R-13
3R-4917 in13.3 inR-38R-19
4A and 4BR-6020½ in16.1 inR-49R-19
4C, 5 and 6R-6020½ in16.1 inR-49R-30
7 and 8R-6020½ in16.1 inR-49R-38

ENERGY STAR heads its attic columns as insulation to add, so with three to four inches already in place, add the R-value in the fifth column. Its floor column is the level for an insulated floor; crawl space walls have their own code levels in the crawl space encapsulation guide.

R-49 and R-60 insulation thickness

R-49 is 14 inches as a PINK Next Gen batt, the thickest on the sheet, 17 inches of AttiCat fiberglass, or 14.3 inches of cellulose blown in to settle at 13.3.

No batt on the sheet reaches R-60, so it is blown in or built from layers: 20½ inches of AttiCat fiberglass, about 31.5 bags for every thousand square feet, or 17.3 inches of cellulose that settles to 16.1. Either way the attic needs that much room below the roof deck and its vents.

Batt insulation thickness chart

Batts come in set thicknesses, and a higher R-value is not always thicker: the R-21 batt is 5½ inches, an inch less than the R-19 at 6½, and R-13 and R-15 are both 3½ inches.

Owens Corning PINK Next Gen batts, unfaced and kraft-faced.
BattThicknessNote
R-113½ inkraft-faced
R-133½ in
R-153½ in
R-196½ in
R-205½ in
R-215½ in
R-226¾ in
R-235½ in
R-258 in
R-30C8¼ in
R-3010 in
R-38C10¼ inC batt, for cathedral ceilings
R-3812½ in
R-4914 in

Blown-in insulation depth and settling

Loose cellulose settles after it is blown in, so Greenfiber’s chart gives two depths for each R-value: how deep to blow it, and the depth it settles to and is rated at. For R-38 that is 11.2 inches blown and 10.4 settled. Owens Corning’s AttiCat chart lists the same number for its minimum thickness and its minimum settled thickness.

Check the depth in several places and blow to the deeper figure. Greenfiber’s chart says to put in both the bags per 1,000 square feet and the installed thickness it lists to reach the stated R-value, so count bags as well as inches.

Spray foam thickness

Spray foam is rated per inch, so its depth is the R-value divided by the rating: Huntsman rates its closed-cell Heatlok HFO High Lift at R-7.4 per inch and its open-cell Classic Ultra Select at R-3.7. The spray foam calculator turns an area and a target R-value into board feet, sets and kits.

Insulation thickness FAQ

How thick is R-38 insulation?

About 12½ inches as an Owens Corning PINK Next Gen batt, or 10¼ inches for its R-38C cathedral batt. Blown in, it is 13½ inches of AttiCat fiberglass or 10.4 inches of settled Greenfiber cellulose.

How thick is R-60 insulation?

No batt on Owens Corning’s sheet reaches R-60, so it is blown in or built from layers: 20½ inches of AttiCat fiberglass, or 17.3 inches of Greenfiber cellulose blown in to settle at 16.1.

How thick is R-49 insulation?

14 inches as a PINK Next Gen batt, 17 inches of AttiCat blown fiberglass, or 13.3 inches of settled Greenfiber cellulose.

How deep should attic insulation be?

Deep enough for your zone’s R-value. ENERGY STAR recommends R-49 for an uninsulated attic in zones 2 and 3 and R-60 in zones 4 through 8; in AttiCat blown fiberglass that is 17 or 20½ inches.

How thick is R-30 insulation?

10 inches as a PINK Next Gen batt (8¼ inches for the R-30C cathedral batt), 10¾ inches of AttiCat fiberglass, or 8.3 inches of settled cellulose.

Does blown-in insulation settle?

Cellulose does: Greenfiber’s chart has R-38 blown to 11.2 inches and rates it at the 10.4 inches it settles to. Owens Corning’s AttiCat chart gives the same depth before and after settling, 13½ inches at R-38.

Sources & method

Batt thicknesses are from Owens Corning’s PINK Next Gen data sheet (October 2024), blown fiberglass depths from its AttiCat coverage chart, cellulose depths from Greenfiber’s SANCTUARY coverage chart, and the zone levels from ENERGY STAR. Spray foam depths divide the R-value by the per inch ratings on Huntsman’s data sheets. Other brands publish their own charts with their own numbers.

  1. Owens Corning. PINK Next Gen Fiberglas Insulation Product Data Sheet (Pub. No. 10024913-A). October 2024
  2. Owens Corning. AttiCat PINK Blown-In Insulation, coverage chart. retrieved Nov 15, 2026
  3. US Greenfiber. SANCTUARY Attic Application Coverage Chart, 25 lb bag (DM-6.3-38 Rev F 05-26). Rev F 05-26
  4. ENERGY STAR (U.S. EPA). Recommended Home Insulation R-Values. retrieved Nov 15, 2026
  5. Huntsman Building Solutions. Classic Ultra Select Technical Data Sheet (AN 20.00178). REV 02.10.22
  6. Huntsman Building Solutions. Heatlok HFO High Lift Sell Sheet (AN 20.00060). REV 06.21.22
  7. Owens Corning. R-38C EcoTouch PINK Fiberglas Insulation for 2x12 Cathedral Ceilings, Product Data Sheet (Pub. No. 21151-D). June 2012